Low Flow

Bernoulli's equation states that the pressure drop across a constriction is proportional to the square of the flow rate. Using this equation, smart differential pressure transmitters can infer the flow.

In this type of application, it is not only important to have an accurate differential pressure transmitter, but also an accurate "constriction". It is the accuracy of the total system that must be considered.

Therefore, Yokogawa combines our DP transmitter with an Integral Flow Orifice (IFO) in one unit to produce a total system to measure low flow accurately.

  EJA115E EJX115A
Accuracy
± 0.040%  
± 0.055%  
Accuracy (Integral Orifice)
± 5%
Stability
± 0.1% of URL per 10 years  
± 0.1% of URL per 7 years  
Response Time
90 msec
Safety
FMEDA Report
IEC 61508 Certified (SIL 2)
Specification Conformance
±3σ

EJA115E

Differential Pressure Transmitter attached to an IFO assembly based on the EJA-E Series.

EJX115A